ATS22C14Q

Schneider Electric

Product Lifecycle: Active

soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 37 to 75kW

ATS22C14Q

soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 37 to 75kW

  • Maximum Switching Current5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs
  • Protection TypePhase failure line Thermal protection motor Thermal protection starter
  • Motor Power Kw37 kW 230 V 75 kW 400 V 75 kW 440 V
  • Discrete Output TypeRelay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
  • Motor Power Range AC-330…50 kW 200…240 V 3 phase 55…100 kW 380…440 V 3 phase
  • Device ConnectionIn the motor supply line To the motor delta terminals
  • Depth9.04 in (229.5 mm)
  • Motor Starter TypeSoft starter
  • Net Weight39.68 lb(US) (18 kg)
  • Width5.91 in (150 mm)
  • Type Of CoolingForced convection
  • Operating PositionVertical +/- 10 degree
  • MarkingCE
  • Transmission Rate4800, 9600 or 19200 bps
  • Communication Data LinkSerial
  • Physical InterfaceRS485 multidrop
  • Connector Type1 RJ45
  • PTC Probe Input750 Ohm
  • Communication Port ProtocolModbus
  • Output Current0.4...1 Icl adjustable
  • Discrete Input LogicPositive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
  • Minimum Switching Current100 mA 12 V DC relay outputs)
  • Height14.02 in (356 mm)
  • Installed Device31
  • Discrete Input Voltage24 V <= 30 V
  • Discrete Input Number3
  • Discrete Input TypeLI1, LI2, LI3) logic, 5 mA 4.3 kOhm
  • Discrete Output Number2
  • [Uc] Control Circuit Voltage230 V - 15...10 % 50/60 Hz
  • Control Circuit Consumption20 W
  • Network Frequency45...66 Hz
  • Assembly StyleWith heat sink
  • Supply Frequency50...60 Hz - 10...10 %
  • Type Of StartStart with torque control (current limited to 3.5 In)
  • Function AvailableInternal bypass
  • Supply Voltage Limits195…484 V
  • IP Degree Of ProtectionIP00
  • Icl Starter Rating140 A connection in the motor supply line for standard applications
  • Utilisation CategoryAC-53A
  • [Us] Rated Supply Voltage230...440 V - 15...10 %
  • Component NameATS22
  • Factory Setting Current131 A
  • Phase3 phase
  • Product DestinationAsynchronous motors
  • Power Dissipation In W82 W for standard applications
  • Product Specific ApplicationPumps and fans
  • Product Or Component TypeSoft starter
  • Range Of ProductAltistart 22

Get a quick quote

Select Qty:

Average response time:

11 minutes

This part can ship within 24h!

Fast worldwide Shipping and Delivery

Shipping cost will be calculated during checkout


Payments methods

Secure Payment Processing
with money back guarantee

1 year warranty on all parts


Responsive Customer Support
with personalized assistance


Need more details?

Feel free to chat with us.

Friendly Powermatic robot

What can I help you find today?