ATS22D62Q

Schneider Electric

Product Lifecycle: Active

soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 15 to 30kW

ATS22D62Q

soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 15 to 30kW

  • Maximum Switching Current5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs
  • Protection TypePhase failure line Thermal protection motor Thermal protection starter
  • Motor Power Kw15 kW 230 V 30 kW 400 V 30 kW 440 V
  • Motor Power Range AC-315…25 kW 200…240 V 3 phase 30…50 kW 380…440 V 3 phase
  • Device ConnectionTo the motor delta terminals In the motor supply line
  • Discrete Output TypeRelay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
  • Depth8.15 in (207 mm)
  • Net Weight26.46 lb(US) (12 kg)
  • Motor Starter TypeSoft starter
  • Height11.61 in (295 mm)
  • Operating PositionVertical +/- 10 degree
  • Type Of CoolingForced convection
  • MarkingCE
  • Installed Device31
  • Width5.71 in (145 mm)
  • Physical InterfaceRS485 multidrop
  • Transmission Rate4800, 9600 or 19200 bps
  • Connector Type1 RJ45
  • Communication Port ProtocolModbus
  • Communication Data LinkSerial
  • PTC Probe Input750 Ohm
  • Discrete Input TypeLI1, LI2, LI3) logic, 5 mA 4.3 kOhm
  • Output Current0.4...1 Icl adjustable
  • Discrete Input Number3
  • Discrete Input LogicPositive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
  • Discrete Input Voltage24 V <= 30 V
  • Minimum Switching Current100 mA 12 V DC relay outputs)
  • Discrete Output Number2
  • Control Circuit Consumption20 W
  • Supply Frequency50...60 Hz - 10...10 %
  • [Uc] Control Circuit Voltage230 V - 15...10 % 50/60 Hz
  • Type Of StartStart with torque control (current limited to 3.5 In)
  • Icl Starter Rating62 A connection in the motor supply line for standard applications
  • Supply Voltage Limits195…484 V
  • Function AvailableInternal bypass
  • Assembly StyleWith heat sink
  • Network Frequency45...66 Hz
  • IP Degree Of ProtectionIP20
  • Utilisation CategoryAC-53A
  • Power Dissipation In W59 W for standard applications
  • [Us] Rated Supply Voltage230...440 V - 15...10 %
  • Factory Setting Current57 A
  • Phase3 phase
  • Component NameATS22
  • Product Specific ApplicationPumps and fans
  • Product Or Component TypeSoft starter
  • Product DestinationAsynchronous motors
  • Range Of ProductAltistart 22

Get a quick quote

Select Qty:

Average response time:

11 minutes

This part can ship within 24h!

Fast worldwide Shipping and Delivery

Shipping cost will be calculated during checkout


Payments methods

Secure Payment Processing
with money back guarantee

1 year warranty on all parts


Responsive Customer Support
with personalized assistance


Need more details?

Feel free to chat with us.

Friendly Powermatic robot

What can I help you find today?