LC1D115P7

Schneider Electric

Product Lifecycle: Active

IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 230VAC 50/60Hz coil, open

LC1D115P7

IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 230VAC 50/60Hz coil, open

  • Product CertificationsLROS (Lloyds register of shipping) RINA DNV GOST BV GL CCC CSA UL UKCA
  • Motor Power Kw30 kW 220...230 V AC 50/60 Hz AC-3) 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415...440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 65 kW 1000 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/
  • [Icw] Rated Short-Time Withstand Current250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling ci
  • [Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power HP (UL / CSA)30 hp 200/208 V at AC 50/60 Hz for 3 phase 40 hp 230/240 V at AC 50/60 Hz for 3 phase 75 hp 460/480 V at AC 50/60 Hz for 3 phase 100 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
  • Tightening TorqueControl circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
  • Irms Rated Making Capacity1260 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation CategoryAC-1 AC-4 AC-3
  • Associated Fuse Rating250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit
  • Control Circuit Voltage Limits0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz 1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
  • Hold-In Power Consumption In VA2…18 VA 60 Hz 0.3 68 °F (20 °C)) 2…18 VA 50 Hz 0.3 68 °F (20 °C))
  • Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Inrush Power In VA280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C))
  • [Ie] Rated Operational Current200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Power Dissipation Per Pole24 W AC-1 7.9 W AC-3
  • Operating Time6...20 ms opening 20...50 ms closing
  • Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Electrical Durability0.8 Mcycles 200 A AC-1 <= 440 V 0.95 Mcycles 115 A AC-3 <= 440 V
  • Contactor ApplicationMotor control Resistive load
  • Mounting SupportRail Plate
  • [Ue] Rated Operational VoltagePower circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
  • Insulation Resistance> 10 MOhm signalling circuit
  • Minimum Switching Voltage17 V signalling circuit
  • Signalling Circuit Frequency25...400 Hz
  • Minimum Switching Current5 mA signalling circuit
  • Heat Dissipation3…8 W 50/60 Hz
  • Maximum Operating Rate2400 cyc/h 60 °C
  • Front CoverWith
  • Average Impedance0.6 mOhm - Ith 200 A 50 Hz power circuit
  • Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
  • Mechanical Durability8 Mcycles
  • Rated Breaking Capacity1100 A 440 V power circuit IEC 60947
  • [Ith] Conventional Free Air Thermal Current200 A 140 °F (60 °C) power circuit
  • Overvoltage CategoryIII
  • [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
  • Auxiliary Contact Composition1 NO + 1 NC
  • [Uc] Control Circuit Voltage230 V AC 50/60 Hz
  • Control Circuit TypeAC 50/60 Hz
  • Poles Description3P
  • Device Short NameLC1D
  • Power Pole Contact Composition3 NO
  • Product Or Component TypeContactor
  • RangeTeSys
  • Product NameTeSys D

$479.00

Select Qty:

$479.00

$479.00 each

Average response time:

11 minutes

This part can ship within 24h!

Fast worldwide Shipping and Delivery

Shipping cost will be calculated during checkout


Payments methods

Secure Payment Processing
with money back guarantee

1 year warranty on all parts


Responsive Customer Support
with personalized assistance


Need more details?

Feel free to chat with us.

Friendly Powermatic robot

What can I help you find today?