LC1D40AM7

Schneider Electric

Product Lifecycle: Active

IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

LC1D40AM7

IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

  • StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Icw] Rated Short-Time Withstand Current320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Motor Power Kw18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
  • [Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
  • Control Circuit Voltage Limits0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Product CertificationsCCC GOST UL CSA
  • Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
  • Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
  • Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
  • Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
  • Utilisation CategoryAC-1 AC-4 AC-3
  • Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Inrush Power In VA140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
  • Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • [Ie] Rated Operational Current60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • [Ue] Rated Operational VoltagePower circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Power Dissipation Per Pole2.4 W AC-3 5.4 W AC-1
  • Mounting SupportPlate Rail
  • Electrical Durability1.4 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
  • Operating Time4...19 ms opening 12...26 ms closing
  • Hold-In Power Consumption In VA13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
  • Contactor ApplicationResistive load Motor control
  • [Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
  • Signalling Circuit Frequency25...400 Hz
  • Heat Dissipation4…5 W 50/60 Hz
  • Minimum Switching Voltage17 V signalling circuit
  • Minimum Switching Current5 mA signalling circuit
  • Mechanical Durability6 Mcycles
  • Coil TechnologyWithout built-in suppressor module
  • Rated Breaking Capacity800 A 440 V power circuit IEC 60947
  • Insulation Resistance> 10 MOhm signalling circuit
  • Maximum Operating Rate3600 cyc/h 140 °F (60 °C)
  • Front CoverWith
  • Average Impedance1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Overvoltage CategoryIII
  • [Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
  • Auxiliary Contact Composition1 NO + 1 NC
  • Control Circuit TypeAC 50/60 Hz
  • [Uc] Control Circuit Voltage220 V AC 50/60 Hz
  • Power Pole Contact Composition3 NO
  • Poles Description3P
  • Product Or Component TypeContactor
  • Device Short NameLC1D
  • Product NameTeSys D
  • RangeTeSys

Get a quick quote

Select Qty:

Average response time:

11 minutes

This part can ship within 24h!

Fast worldwide Shipping and Delivery