Product details
- [Icw] Rated Short-Time Withstand Current320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- [Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
- Motor Power Kw18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
- StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Product CertificationsCSA CCC UL GOST
- Control Circuit Voltage Limits0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
- Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
- Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
- Utilisation CategoryAC-3 AC-4 AC-1
- Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
- Operating Time4...19 ms opening 12...26 ms closing
- Mounting SupportPlate Rail
- [Ie] Rated Operational Current60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Electrical Durability1.4 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
- Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Inrush Power In VA140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
- Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Hold-In Power Consumption In VA13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
- Power Dissipation Per Pole2.4 W AC-3 5.4 W AC-1
- Contactor ApplicationMotor control Resistive load
- Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- [Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
- Insulation Resistance> 10 MOhm for signalling circuit
- Minimum Switching Voltage17 V signalling circuit
- Heat Dissipation4…5 W 50/60 Hz
- Coil TechnologyWithout built-in suppressor module
- Minimum Switching Current5 mA signalling circuit
- Signalling Circuit Frequency25...400 Hz
- Maximum Operating Rate3600 cyc/h 140 °F (60 °C)
- Mechanical Durability6 Mcycles
- Front CoverWith
- Average Impedance1.5 mOhm - Ith 60 A 50 Hz power circuit
- Rated Breaking Capacity800 A 440 V power circuit IEC 60947
- Overvoltage CategoryIII
- [Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
- Auxiliary Contact Composition1 NO + 1 NC
- [Uc] Control Circuit Voltage240 V AC 50/60 Hz
- Control Circuit TypeAC at 50/60 Hz
- Product Or Component TypeContactor
- RangeTeSys
- Device Short NameLC1D
- Poles Description3P
- Power Pole Contact Composition3 NO
- Product NameTeSys D
Get a quick quote
Select Qty:
Average response time:
11 minutes
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.