LC1D95U7

Schneider Electric

Product Lifecycle: Active

IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

LC1D95U7

IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 240VAC 50/60Hz coil, open style

  • Product CertificationsIECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL
  • StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
  • [Icw] Rated Short-Time Withstand Current1100 A 104 °F (40 °C) - 1 s power circuit 800 A 104 °F (40 °C) - 10 s power circuit 400 A 104 °F (40 °C) - 1 min power circuit 135 A 104 °F (40 °C) - 10 min power circuit 140 A - 100 ms signalling circuit 120 A - 500 ms signalling
  • Motor Power Kw25 kW 220...230 V AC 50 Hz AC-3) 45 kW 380...400 V AC 50 Hz AC-3) 45 kW 415...440 V AC 50 Hz AC-3) 55 kW 500 V AC 50 Hz AC-3) 45 kW 660...690 V AC 50 Hz AC-3) 45 kW 1000 V AC 50 Hz AC-3)
  • Motor Power HP (UL / CSA)7.5 hp 115 V at AC 60 Hz for 1 phase 15 hp 230/240 V at AC 60 Hz for 1 phase 25 hp 200/208 V at AC 60 Hz for 3 phase 30 hp 230/240 V at AC 60 Hz for 3 phase 60 hp 460/480 V at AC 60 Hz for 3 phase 60 hp 575/600 V at AC 60 Hz for 3
  • Control Circuit Voltage Limits0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
  • [Ui] Rated Insulation VoltagePower circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Tightening TorqueControl circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in
  • Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
  • Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flex
  • Irms Rated Making Capacity1100 A 440 V AC power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation CategoryAC-3 AC-4 AC-1
  • Safety Reliability LevelB10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
  • Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Mounting SupportRail Plate
  • Electrical Durability1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1
  • Operating Time20...35 ms closing 6...20 ms opening
  • Hold-In Power Consumption In VA26 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C))
  • Power Dissipation Per Pole12.5 W AC-1 7.2 W AC-3
  • Contactor ApplicationMotor control Resistive load
  • [Ie] Rated Operational Current95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit 125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit
  • [Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 125 A 140 °F (60 °C) power circuit
  • Inrush Power In VA245 VA 60 Hz 0.75 68 °F (20 °C)) 245 VA 50 Hz 0.75 68 °F (20 °C))
  • Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Insulation Resistance> 10 MOhm signalling circuit
  • Heat Dissipation6…10 W 50/60 Hz
  • Minimum Switching Voltage17 V signalling circuit
  • Signalling Circuit Frequency25...400 Hz
  • Minimum Switching Current5 mA signalling circuit
  • Maximum Operating Rate3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability4 Mcycles
  • Coil TechnologyWithout built-in suppressor module
  • Front CoverWith
  • Average Impedance0.8 mOhm - Ith 125 A 50 Hz power circuit
  • Rated Breaking Capacity1100 A 440 V power circuit IEC 60947
  • Overvoltage CategoryIII
  • [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
  • Auxiliary Contact Composition1 NO + 1 NC
  • [Uc] Control Circuit Voltage240 V AC 50/60 Hz
  • Control Circuit TypeAC 50/60 Hz
  • RangeTeSys
  • Power Pole Contact Composition3 NO
  • [Ue] Rated Operational VoltagePower circuit 1000 V AC 25...400 Hz
  • Poles Description3P
  • Device Short NameLC1D
  • Product Or Component TypeContactor
  • Product NameTeSys D

Get a quick quote

Select Qty:

Average response time:

11 minutes

This part can ship within 24h!

Fast worldwide Shipping and Delivery

Shipping cost will be calculated during checkout


Payments methods

Secure Payment Processing
with money back guarantee

1 year warranty on all parts


Responsive Customer Support
with personalized assistance


Need more details?

Feel free to chat with us.

Friendly Powermatic robot

What can I help you find today?