LC1F225FD
Schneider Electric
Product Lifecycle: Active
FR catalog.xlsx - SM-618
FR catalog.xlsx - SM-618
Product details
- Product CertificationsLROS (Lloyds register of shipping) DNV ABS UL RMRoS BV CB RINA CSA UKCA
- Motor Power Kw110 kW 380...400 V AC 50/60 Hz AC-3) 110 kW 415 V AC 50/60 Hz AC-3) 110 kW 440 V AC 50/60 Hz AC-3) 129 kW 500 V AC 50/60 Hz AC-3) 129 kW 660...690 V AC 50/60 Hz AC-3) 63 kW 220...230 V AC 50/60 Hz AC-3) 40 kW 400 V AC 50/60 H
- [Icw] Rated Short-Time Withstand Current1800 A 104 °F (40 °C) - 10 s 1000 A 104 °F (40 °C) - 30 s 850 A 104 °F (40 °C) - 1 min 560 A 104 °F (40 °C) - 3 min 440 A 104 °F (40 °C) - 10 min
- StandardsIEC 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1
- Motor Power Range55…100 kW 200…240 V 3 phase 110…220 kW 480…500 V 3 phase 110…220 kW 380…440 V 3 phase
- Connections - TerminalsControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
- Utilisation CategoryAC-4 AC-3 AC-1
- Tightening TorqueControl circuit 10.62 lbf.in (1.2 N.m) Power circuit 309.78 lbf.in (35 N.m)
- Power Dissipation Per Pole32 W AC-1 16 W AC-3
- Control Circuit Voltage LimitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))
- Contactor ApplicationResistive load Motor control
- [Ie] Rated Operational Current315 A 104 °F (40 °C)) <= 440 V AC-1 225 A 131 °F (55 °C)) <= 440 V AC-3
- Associated Fuse Rating315 A gG <= 440 V 250 A aM <= 440 V
- Operating Time30...40 ms closing 30...50 ms opening
- [Ue] Rated Operational Voltage<= 460 V DC <= 690 V AC 50/60 Hz
- [Ui] Rated Insulation Voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
- Heat Dissipation5 W
- Mechanical Durability10 Mcycles
- Hold-In Power Consumption In W5 W 68 °F (20 °C)
- Inrush Power In W800 W 68 °F (20 °C))
- [Ith] Conventional Free Air Thermal Current315 A 104 °F (40 °C)
- Motor Starter TypeDirect on-line contactor
- Compatibility CodeLC1F
- Contactor Coil Voltage110 V DC standard
- Maximum Operating Rate2400 cyc/h 131 °F (55 °C)
- Mounting SupportPlate
- Rated Breaking Capacity1800 A IEC 60947-4-1
- Coil TypeStandard
- Average Impedance0.32 mOhm - Ith 315 A 50 Hz
- Overvoltage CategoryIII
- [Uimp] Rated Impulse Withstand Voltage8 kV
- [Uc] Control Circuit Voltage110 V DC
- Power Pole Contact Composition3 NO
- Poles Description3P
- Product Or Component TypeContactor
- Device Short NameLC1F
- Product NameTeSys F
- RangeTeSys
Get a quick quote
Select Qty:
Average response time:
11 minutes
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.