voltage control relay, Harmony Control Relays, 8A, 2CO, 80…300V AC DC, 110…240V AC DC
voltage control relay, Harmony Control Relays, 8A, 2CO, 80…300V AC DC, 110…240V AC DC
Product details
- Utilisation CategoryAC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1
- Connections - TerminalsScrew terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
- Measurement Error< 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation
- Status LEDRelay ON LED Yellow) Power ON LED Green)
- Safety Reliability DataMTTFd = 433.7 years B10d = 400000
- Repeat Accuracy+/- 0.5 % input and measurement circuit +/- 2 % time delay
- Width0.89 in (22.5 mm)
- Net Weight0.20 lb(US) (0.09 kg)
- Contacts MaterialCadmium free
- Mechanical Durability10000000 cycles
- Electrical Durability100000 cycles
- Mounting Support35 mm DIN rail conforming to EN/IEC 60715
- Tightening Torque5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
- Housing MaterialSelf-extinguishing plastic
- Insulation Resistance> 100 MOhm 500 V DC IEC 60255-27
- Mounting PositionAny position
- Overvoltage CategoryIII IEC 60664-1
- Response Time<= 500 ms
- Nominal Output Current8 A
- Run-Up Delay At Power-Up600 ms
- Maximum Measuring Cycle250 ms measurement cycle as true rms value
- Maximum Power Consumption In W2 W DC
- Hysteresis5…50 % adjustable threshold setting
- Output Contacts2 C/O
- Supply Voltage Frequency50...60 Hz +/- 10 %
- Minimum Switching Current10 mA 5 V DC
- Contacts Type And Composition2 C/O
- Power Consumption In VA5 VA AC
- Reset Time1500 ms at maximum voltage
- Supply Voltage Limits60…280 V AC
- Maximum Switching Voltage250 V AC
- [Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz
- Maximum Switching Current8 A AC
- Measurement Range80...300 V voltage AC/DC 50/60 Hz
- Phase1 phase
- Relay NameRM22UA
- Time Delay TypeAdjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
- Switching Capacity In VA2000 VA
- Relay Monitored ParametersOvervoltage and undervoltage detection
- Supply Circuit TypeDC
- Relay TypeVoltage control relay
- Product Or Component TypeVoltage control relay
- Range Of ProductHarmony Control Relays
Get a quick quote
Select Qty:
Average response time:
11 minutes
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.