TM221CE40R
Schneider Electric
Product Lifecycle: Active
logic controller, Modicon M221, 40 IO, relay, Ethernet
logic controller, Modicon M221, 40 IO, relay, Ethernet
Product details
- Local Signallingfor PWR 1 LED (green) for RUN 1 LED (green) for module error (ERR) 1 LED (red) for SD card access (SD) 1 LED (green) for BAT 1 LED (red) for I/O state 1 LED per channel (green) for SL 1 LED (green) for ACT Etherne
- Response Time35 µs turn-off, I2...I5 input 10 ms turn-on output 10 ms turn-off output 5 µs turn-on, I0, I1, I6, I7 fast input 35 µs turn-on, other terminals input 5 µs turn-off, I0, I1, I6, I7 fast input 100 µs turn-off, other terminals i
- InsulationBetween input and internal logic 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Between supply and ground 1500 V AC Between sensor power supply and ground 500 V AC Between in
- Electrical Connectionremovable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 for connecting the 24 V DC power supply connector, 4 for analogue inputs Mini B USB 2.0 connector for a programming terminal
- Electrical Durability100000 cycles AC-12, 120 V, 240 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, resistive 300000 cycles AC-12, 240 V, 160 VA, resistive 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, i
- Communication ServiceDHCP client Modbus TCP client Ethernet/IP adapter Modbus TCP server Modbus TCP slave device
- Maximum Size Of Object Areas8000 %MW memory words 255 %TM timers 512 %KW constant words 255 %C counters 512 %M memory bits
- Maximum Cable Distance Between DevicesShielded cable <32.81 ft (10 m) fast input Unshielded cable <98.43 ft (30 m) output Unshielded cable <98.43 ft (30 m) digital input Unshielded cable <3.28 ft (1 m) analog input
- Counter FunctionSingle phase A/B Pulse/direction
- Input Impedance3.4 kOhm discrete input 100 kOhm analog input 4.9 kOhm fast input
- Transmission Rate1.2...115.2 kbit/s (115.2 kbit/s by default) 49.21 ft (15 m) RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.84 ft (3 m) RS232 480 Mbit/s USB
- Mounting SupportTop hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit
- Configurable Filtering Time0 ms input 3 ms input 12 ms input
- Communication Port ProtocolUSB port USB - SoMachine-Network Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet
- Integrated Connection TypeUSB port mini B USB 2.0 Non isolated serial link serial 1 RJ45 RS232/RS485 Ethernet RJ45
- Discrete Output Voltage5...125 V DC 5...250 V AC
- Output Voltage Limits125 V DC 277 V AC
- Permitted Overload On Inputs+/- 30 V DC 5 min maximum)analog input +/- 13 V DC permanent)analog input
- Discrete Input Current7 mA discrete input 5 mA fast input
- Memory Capacity256 kB user application and data RAM 10000 instructions 256 kB internal variables RAM
- Power Supply Output Current0.52 A 5 V expansion bus 0.24 A 24 V expansion bus
- Maximum Power Consumption In VA70 VA 100...240 V with max number of I/O expansion module 41 VA 100...240 V without I/O expansion module
- Execution Time Per Instruction0.2 µs Boolean
- Backup Time1 year 77 °F (25 °C) by interruption of power supply)
- Protection TypeWithout protection 5 A
- Minimum Load1 mA 5 V DC relay output
- Battery TypeBR2032 lithium non-rechargeable 4 year(s)
- Data Storage Equipment2 GB SD card optional)
- Data Backed Up256 kB built-in flash memory backup of application and data
- Switching Frequency20 switching operations/minute with maximum load
- Mechanical Durability20000000 cycles relay output
- Reset Time1 s
- Maximum Current Per Output Common7 A
- Absolute Accuracy Error+/- 1 % of full scale analog input
- Voltage State 0 Guaranteed<= 5 V input
- Discrete Input Voltage24 V
- Voltage State 1 Guaranteed>= 15 V input
- Conversion Time1 ms per channel + 1 controller cycle time analog input
- Analogue Input Resolution10 bits
- Discrete Input Voltage TypeDC
- Discrete Input LogicSink or source (positive/negative)
- Network Frequency50/60 Hz
- Inrush Current40 A
- Maximum Number Of I/O Expansion Module7 relay output
- Supply Voltage Limits85…264 V
- Discrete Output Current2 A
- [Us] Rated Supply Voltage100...240 V AC
- Discrete Input Number24, discrete input IEC 61131-2 Type 1
- Product Or Component TypeLogic controller
- Range Of ProductModicon M221
- Discrete Output TypeRelay normally open
- LSB Value10 mV
- Net Weight1.01 lb(US) (0.456 kg)
- Width6.30 in (160 mm)
- Height3.54 in (90 mm)
- Depth2.76 in (70 mm)
- MarkingCE
- Sensor Power Supply24 V DC 250 mA supplied by the controller
- Port Ethernet10BASE-T/100BASE-TX 1 328.08 ft (100 m) copper cable
- SupplySerial)serial link supply 5 V, <200 mA
- Regulation LoopAdjustable PID regulator up to 14 simultaneous loops
- Counting Input Number4 fast input (HSC mode) 100 kHz 32 bits
- Clock Drift<= 30 s/month 77 °F (25 °C)
- Realtime ClockWith
- Exct Time For Event Task60 µs response time
- Execution Time For 1 Kinstruction0.3 ms event and periodic task
- Discrete I/O Number40
- Discrete Output Number16 relay
- Analogue Input Number2 0...10 V
Get a quick quote
Select Qty:
Average response time:
11 minutes
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.