- Product CertificationsRINA RMRoS ABS CCC BV DNV LROS (Lloyds register of shipping) CB UL UKCA
- Motor Power Kw160 kW 380...400 V AC 50/60 Hz AC-3) 180 kW 415 V AC 50/60 Hz AC-3) 200 kW 440 V AC 50/60 Hz AC-3) 200 kW 500 V AC 50/60 Hz AC-3) 220 kW 660...690 V AC 50/60 Hz AC-3) 160 kW 1000 V AC 50/60 Hz AC-3) 100 kW 220...230 V AC 50/6
- StandardsEN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1
- [Icw] Rated Short-Time Withstand Current2650 A 104 °F (40 °C) - 10 s 1800 A 104 °F (40 °C) - 30 s 1300 A 104 °F (40 °C) - 1 min 900 A 104 °F (40 °C) - 3 min 750 A 104 °F (40 °C) - 10 min
- Connections - TerminalsControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
- Utilisation CategoryAC-4 AC-3 AC-1
- Power Dissipation Per Pole44 W AC-1 31 W AC-3
- [Ie] Rated Operational Current400 A 104 °F (40 °C)) <= 440 V AC AC-1 330 A 131 °F (55 °C)) <= 440 V AC AC-3
- Operating Time40...65 ms closing 100...170 ms opening
- Control Circuit Voltage LimitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 40...400 Hz 131 °F (55 °C))
- Tightening TorqueControl circuit 10.62 lbf.in (1.2 N.m) Power circuit 309.78 lbf.in (35 N.m)
- Contactor ApplicationMotor control Resistive load
- Associated Fuse Rating400 A aM <= 440 V 500 A gG <= 440 V
- [Ui] Rated Insulation Voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
- [Ue] Rated Operational Voltage<= 1000 V AC 50/60 Hz <= 460 V DC
- Mechanical Durability10 Mcycles
- Compatibility CodeLC1F
- Maximum Operating Rate2400 cyc/h 131 °F (55 °C)
- Mounting SupportPlate
- Hold-In Power Consumption In VA10 VA 40...400 Hz 0.9 68 °F (20 °C))
- Heat Dissipation8 W
- Inrush Power In VA650 VA 40...400 Hz 0.9 68 °F (20 °C))
- Average Impedance0.28 mOhm - Ith 400 A 50 Hz
- Rated Breaking Capacity2640 A IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current400 A 104 °F (40 °C)
- [Uc] Control Circuit Voltage24 V AC 40...400 Hz
- Overvoltage CategoryIII
- [Uimp] Rated Impulse Withstand Voltage8 kV
- RangeTeSys
- Power Pole Contact Composition3 NO
- Product NameTeSys F
- Poles Description3P
- Product Or Component TypeContactor
- Device Short NameLC1F
Get a quick quote
Select Qty:
Average response time:
11 minutes
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.